For concrete with aggregates less than 3 inches, the thermometer must remain in the
fresh concrete sample a minimum of 5 minutes or until the temperature reading
stabilizes. (T or F)
False (2-5 minutes)
The temperature measuring device must be accurate to within 0.1 degree. (T or F)
False
The temperature measuring device shall have a capacity of measuring temperature of
freshly mixed concrete throughout a range of _____ to _____ degree F ( ______ to
______ degree C)
30 to 120 degree F (0 to 50 degree C)
A composite sample is not needed if only the temperature test is being run. (T or F)
True
The temperature of fresh concrete in a placement must be measured by inserting a
thermometer into the top six inches of concrete. (T or F)
False (3 in.)
The temperature of the concrete is recorded to the nearest ______ degree F (______
degree C)
1 degree F (0.5 degree C)
ASTM C1064 states the container used to measure temperature of concrete must be
large enough to provide at least 5 inches of concrete around the sensor. (T or F)
False (The container shall be large enough to provide at least 75mm (3 in) of concrete
in all directions around the sensor of the temperature measuring device)
Calibrate the temperature measuring device at least __________, or whenever there is
a question of accuracy.
Annually
After the thermometer is placed in the concrete:
Gently press concrete around the thermometer