Florida Fire Inspector State Exam Review | Questions and Verified Answers | 100% Correct | 2023/ 2024 Update
Florida Fire Inspector State Exam Review |
Questions and Verified Answers | 100%
Correct | 2023/ 2024 Update
Q: A live fire watch is needed if the fire alarm system is out of service for what length of time
Answer:
Four hours or more
Q: What is a common type of indicating valve
Answer:
OS&Y: outside screw & yoke
Q: What is the maximum travel distance to an exit in a sprinkler protected education building
Answer:
200 feet
Q: What type of electrical outlet should be installed in bathrooms
Answer:
GFCI: ground fault circuit interrupted
Also anywhere water is within 6'6" in kitchens
Q: The smallest diameter heavy timber can be is
Answer:
8 inches
Q: Is plate glass considered safety glass
Answer:
No
Q: What is the common scale used for floor plans
Answer:
1/4 inch equals one foot
Q: Where in a wood working shop is a fire most likely to occur
Answer:
At the dust hogger: the machine that's turns wood scrap into chips or splinters
Q: What is the most critical thing for an inspector to check in a warehouse
Answer:
The automatic sprinkler system
Q: According to NFPA 1 what is a highly volatile liquid
Answer:
A liquid with a boiling point of less than 68 degrees F
Q: What is fire resistance
Answer:
The ability for a structural assembly to maintain its load bearing ability under fire conditions
Q: What is a beam
Answer:
A horizontal structure member used between posts, columns, or walls
Q: What is the activation temperature of an orange head sprinkler
Answer:
500 to 575 degrees F
Classification is ultra high
Q: The thickness of wood used for fire stopping is what
Answer:
No less than 2 inches
Q: What are two types of automatic roof vent designs
Answer:
Fusible link type should not operate below 300 degrees F
Drop out panel type
Q: What is the maximum travel distance on a landing to reach the stairs
Answer:
4 feet
Q: Who has the ultimate authority to make changes in fire codes
Answer:
The AHJ
Q: What are the hazards of dip tank operations
Answer:
Fire involving the liquids and explosions involving vapor and air mixtures
Q: What is the hour rating of the roof in a dry cleaning facility
Answer:
Not less than one hour
Q: What is the discharge size of the inspectors test connections
Answer:
The discharge orifice shall be equal in size to the smallest sprinkler in the system
Q: Fire dampers are activated how
Answer:
By fusible links