According to the IBC, the "blank" is to hire the special inspector. -Answer- owner or owners agent. 2009 IBC Section 1704.1 According to the IBC, the "blank" is the responsible for the approval of a person's qualifications to act as a special inspector. -Answer- code official. 2009 IBC, Section 1704.1 According to the IBC, discrepancy corrections are made known to the building official by: -Answer- final report. 2009 IBC, Section1704.1.2 When is the code official to be made aware of a discrepancy found during a special inspection? -Answer- If it is not corrected by the contractor. 2009 IBC, Section 1704.1.2 According to the Model Program for Special Inspection, the special inspector is to document work that is nonconforming: -Answer- In a written report - Section II B 4 - Model Programs According to the Model Program for Special Inspection, the special inspector is to prepare written report of inspection: -Answer- After each inspection visit - Section II B 5 - Model Programs According to the Model Program for Special Inspection, which of the following items does not need to be included in each inspection report? -Answer- Description of discussions with the contractor - Section B 5 - Model Programs According to the Specification for Structural Joints using high strength bolts, the nominal diameter of standard bolt holes shall be how much larger than the nominal bolt diameter? -Answer- 1/16 inch - Specification for Structural Joints Table 3.1 Discrepancies in the work shall be brought to the immediate attention of the "blank" for corrective action. -Answer- the contractor - 2009 IBC, Section 1704.1.2. The special inspector shall furnish inspection reports to the "blank" and to the "blank"? - Answer- Building Official and Registered Design professional The special inspector shall provide continuos inspection of: -Answer- Single-pass fillet welds greater than 5/16 inch in size - 2099 IBC, Table 1704.3, Item 5.3 The special inspections required by this code are not required where the work is done on the premise of a? -Answer- Approved fabricator - 2009 IBC, Section 1704.2.2 The special inspection of the steel fabrication process shall not be required where the fabricator does not perform any? -Answer- heating operations - 2009 IBC, Section 1704.3, Exceptions # 1 According to the Specifications for Structural Steel Buildings, ASTM Standard "blank" is to be used for the material test for steel sheets. -Answer- A568 - Section A31, Specifications for Structural Steel Buildings According to the Specifications for Structural Steel Buildings, the "blank" conducts the material tests for identification of the structural steel. -Answer- Fabricator or Testing Laboratory - Section A31, Specifications for Structural Steel Buildings. According to the Specifications for Structural Steel Buildings, which of the following steel members are allowed to be unidentified steel? -Answer- Unimportant members, where their physical properties and weldability would not affect the structure strength - Section A31b, Specifications for Structural Steel Buildings According to the Code of Standard Practice for Steel Buildings and Bridges, how is steel of special material to be identified? -Answer- It is marked by the supplier - Section 5.1.1, Code of Standard Practice for Steel Buildings and Bridges According to the Code of Standard Practice for Steel Buildings and Bridges, how are fabricators stock steel material identified? -Answer- Certified mill test reports - Section 5.2.2 - Code of Standard Practice for Steel Buildings and Bridges According to the Specification for Structural Steel Buildings, what ASTM Standard would apply to a sample for structural steel pipe? -Answer- A53 - Section A31a - Specification for Structural Steel Buildings According to the Code of Standard Practice for Steel Buildings and Bridges, the number of samples required to be tested for structural steel is: -Answer- The number specified by the ASTM specification - Section 5.1.1 - Code of Standard Practice for Steel Buildings and Bridges According to the Specification for Structural Steel Buildings, which ASTM standard would apply to a sample for structural steel plates? -Answer- A36, A283, and A242 - Section A31a - Specification for Structural Steel Buildings According to the Specification for Structural Steel Buildings, "blank" tests are required for samples for built-up sections consisting of plates over 2 inches in thickness. - Answer- Charpy V-notch testing - Section A31d, Specification for Structural Steel Buildings According to the Specification for Structural Steel Buildings, ASTM standard "blank" would apply to a sample for structural steel bars. -Answer- A36, A529, and A572 - Specification for Structural Steel Buildings Steel furnished for structural load-carrying purposes shall be properly : -AnswerIdentified - 2009 IBC, Section 2203.1
Category | exam bundles |
Comments | 0 |
Rating | |
Sales | 0 |