ICC CALIFORNIA UST SERVICE TECHNICIAN CERTIFICATION ACTUAL EXAM 200 QUESTIONS AND CORRECT DETAILED ANSWERS (100%VERIFIED ANSWERS) |AGRADE

ICC CALIFORNIA UST SERVICE TECHNICIAN CERTIFICATION 2023-

2024 ACTUAL EXAM 200 QUESTIONS AND CORRECT DETAILED

ANSWERS (100%VERIFIED ANSWERS) |AGRADE

Automatic line leak detectors installed on underground piping with secondary

containment shall be capable of detecting a leak of ?

3 gallons per hour at 10 psi

How often should ATG be programmed to test the tank?

At least monthly

According to PEI RP 300, a combustible gas can be used to?

Detect vapor leaks in a vapor recovery system.

According to PEI RP 300, a written scope of work for vapor recovery installation

should include?

Construction plans

Positive shut off overfill protection device must stop the flow of fuel when the tank

is no more then?

95% full

According to Executive Order (EO) VR 201-A , what could cause a nozzle shut off

mechanism or malfunction?

Depended filter seal damage

According to VR 201-A, breakaway reconnection must be?

Logged in GDF log

According to PEI RP 300 what is an INCORRECT method of documenting piping

location?

Sketching a diagram on the inside cover of vapor recovery equipment manual

According to PEI RP 300 as built drawing or pictures of the underground pipping

and other components shall be_________.

maintained as long as UST is in service.


According to EO VR 101-E maintenance records are required to include what?

Name and Designated UST Operator.

The Phil-Tite EVR Phase 1 system require that vapor vent pipes at any UST

system be

Used with no more than 3 p/v valves

According to EO VR 2010 after installing a new spout assembly in the Healy 900

nozzle the following test must be conducted?

Nozzle dispensing shut off test

According to Healy EO VR 201-A a vapor recovery record is to be maintained by?

Gasoline dispensing facility operator(GDF)

An enhanced leak detection test is required within how many feet of a public

drinking well?

1000 feet

What are the components of the Fire Triangle?

Fuel, Heat/Ignition Source, Oxygen

If equipped with an over fill alarm, it must be located?

So it can be seen or heard from the delivery location.

If installed, the following requires independent 3rd party certification to prove

compliance with established regulations.

Automatic Tank Gauge, Liquid Product Detectors, SIR

Where are ATG's installed?

Opening in top of the tank

What is true about ATG's

They're capable of alarming operator of low product level

The following types of releases must be reported to the local agency.


Releases greater than 25 gallons that escape secondary containment. Release that

escape primary containment. Releases less than 25 gallons which escape secondary

containment

If an unauthorized product release meets the requirements for reporting to the local

agency, verbal notification must be made within ____hours, followed by a written

notification within ____days.

24 HRS, 5 DAYS

The following unusual conditions shall be reported to the local agency, EXCEPT:

Water in spill buckets

If the monitoring system detects a leak that has occurred, the local agency must be

notified unless______.

Unless the monitoring device is found to be defective and is immediately repaired.

The written report submitted to the local agency after an unauthorized release is

required to include the following EXCEPT:

Cause of release

An unauthorized release which does not escape secondary containment, requires

only recordation on the Operators Manual Report provided if what criteria is met?

It did not cause deterioration of secondary containment. It did not increase the

hazard of fire. It was cleaned up within eight hours and it was cleaned up within

eight hours detection.

Recording of an authorized release in the operators monitoring records shall

include?

Actions taken to prevent further releases.

If a authorized release meets reporting requirements of Title 23, section 2652, the

report must be filed within the? (Un or A?)

Local agency

Which statement concerning the annual monitor certification is most correct?

Local agencies must be notified 48 hours prior to certification in results must be

submitted within 30 days of certification.

No comments found.
Login to post a comment
This item has not received any review yet.
Login to review this item
No Questions / Answers added yet.
Price $21.00
Add To Cart

Buy Now
Category Exams and Certifications
Comments 0
Rating
Sales 0

Buy Our Plan

We have

The latest updated Study Material Bundle with 100% Satisfaction guarantee

Visit Now
{{ userMessage }}
Processing