The greater the temperature of wet materials, the more energy is
available for __________ to occur. - ANSWER- Evaporation
If a drying chamber is 75 degrees and 40% RH, what is the
humidity ratio? (use psychrometric chart) - ANSWER- 52 gpp
(grains of moisture per pound of dry air)
If a drying chamber is 68 degrees and 70% RH, what is the humidity
ratio? (use psychometric chart) - ANSWER- 72 gpp (grains of moisture
per pound of dry air)
If a drying chamber is 70 degrees and 60 gpp, what is the RH? (use
psychometric chart) - ANSWER- 55%
If the exterior is 42 degrees and 30% RH, what is the humidity ratio?
(use psychometric chart) - ANSWER- 12 gpp (grains of moisture per
pound of dry air)
If a drying chamber is 32% RH and 60gpp, what is the temperature? (use
psychometric chart) - ANSWER- 87 degrees
What is the relative humidity if the dew point temperature is 35 degrees
and the dry bulb temperature is 70 degrees (use psychometric chart) -
ANSWER- 28%
A material that is very weakened when wet, but, if dried properly,
regains its original strength is... - ANSWER- Gypsum (drywall,
wallboard, sheetrock)
The ability for water vapor to move through materials is known as... -
ANSWER- permeability
Classes of water describe - ANSWER- The potential rate of evaporation
(evaporation load)
A drying chamber that has the least amount of area affected (less than
5%) of the combined walls, floors and ceiliing material is ... -
ANSWER- class 1
A class 2 loss is a drying chamber that has a significant amount of
moisture affecting ____________ of the combined walls, floors and
ceiling materials. - ANSWER- 5% - 40%
A drying chamber that has the greatest amount of moisture, affecting
over 40% of the combinded walls, floors and ceiling materials is... -
ANSWER- class 3
A drying chamber that has water bound in materials such as plaster or
hadwood resulting in low potential evaporation is a.... - ANSWER- class
4
If attempting to dry tile over a wood subfloor... - ANSWER- Provide dry
air flow (low humidity) and Increase heat or thermal energy.
What safety features does drying equipment need? (air movers,
dehumidifiers, etc) - ANSWER- grounded plug
What can happen when ducting airflow directly into wall cavities? -
ANSWER- Increase the rate of evaporation
Dehumidifiers balance the drying system by removing moisture from the
air. A balanced drying system is best achieved when the rate of
dehumidification
is _________________________ than or equal to the rate of
evaporation. - ANSWER- greater
How do refrigerant dehumidifiers remove moisture from the air? -
ANSWER- Condensation
Refrigerant dehumidifiers are rated for water removal in ... - ANSWERpints per day (ppd)
Desiccant dehumidifiers remove moisture from the air through principle
of ... - ANSWER- absorption
Since desiccant dehumidifiers do not remove water vapor through
condensations, they are not limited by... - ANSWER- temperature
In an area that measures 15,000 cubic feet, what is the initial AHAM
requirement for a Class 2 loss, using an LGR (refrigerant) dehumidifier?
(use factor chart) - ANSWER- 15,000 cu ft / 50 = 300 ppd pints per day
A class 3 loss that measures 15' x 35' and has a ceiling height of 9', how
many 100-pint LGRs are needed? (refrigerant formula) - ANSWER- 2:
(15 x 30 x 9 = 4050 cu ft/40 (from chart) = 118 pints per day. we need 2
because our LGR only does 100ppd.
A warehouse that measures 35' x 40' x 10' has a class 4 loss, using a
desiccant dehumidifier. How many CFM are required? (desiccant
formula) - ANSWER- 700:
35 x 40 x 10 = 14,00 cu ft. x 3 ACH (air changes per hour) / 60 =
42,000/60 = 700 cfm (cu ft per minute)
To control particles in the air you could install... - ANSWER- An air
filtration device (AFD)