Michigan Builders License Exam Questions and Answers Already Passed
Michigan Builders License Exam
Questions and Answers Already Passed
IRC (International Residential Code) ✔✔Created to serve as a complete, comprehensive code
regulating the construction of single-family, two-family and buildings consisting of three or
more townhouse units.
First 2 chapters of code book are ✔✔Administrative
Plans or supporting documents are almost always required by the controlling authority prior to
issuing a permit. T or F ✔✔True
Does the building official have the authority to render interpretations of the code? ✔✔Yes
None of the following require a permit, EXCEPT:
sidewalks and driveways
tiling
an 8 foot fence
playground equipment ✔✔8 foot fence.
Tables and illustrations are always supported by information found in the written code and
footnotes. T or F ✔✔False
The amount of evenly distributed weight imposed by inhabitants, goods and removable objects
on a floor or roof system is referred to as ✔✔Live load.
If a code requirement is in the book, it is both acceptable and enforceable by the code official. T
or F ✔✔True.
Illustrations are typically referred to as ✔✔Figures.
Generally speaking, the building official's job is to ✔✔Determine that buildings are built to the
minimum enforceable standard.
It is required that all manufacturer instructions be at the jobsite at the time of inspection. T or F
✔✔True.
All of the following are not considered habitable spaces EXCEPT:
bathrooms
kitchens
storage spaces
closets ✔✔Kitchen.
Bathrooms must be provided with an aggregate glazing area no less than _____ square feet, half
of which must be openable. ✔✔3.
The maximum height of an egress window above the floor is ✔✔44 inches.
A basement bedroom must have an egress window with a clear opening of at least ______ square
feet. ✔✔5.7 sq ft.
At least one side-hinged exit door must be in each dwelling unit, and must be _____ feet wide.
✔✔3.
A porch more than _____ inches above grade must be provided with 36" guards. ✔✔30 inches.
Wall and ceiling finishes shall have a flame-spread classification of no more than ______ .
✔✔200.
According to code, concrete must reach at least 70% of it's ability within ____________days.
✔✔7 days.
A stud used for a non-bearing partitions may not be notched more than ____% of the stud width.
✔✔40%.
The Michigan Uniform Energy code applies to new buildings as well as ✔✔Additions,
alterations, renovation and repairs.