1. Since 1992, the United States Department of Energy has required that
all furnaces sold and installed from that date on must have an AFUE of no
less than:
A: 70%
B: 75%
C: 78%
D: 80%✔✔78%
2. Many pre-1992
furnaces have efficiencies around .
A: 10%
B: 40%
C: 60%
2 / 14
D: 80%✔✔60%
3. Today, furnaces
with AFUE ratings greater than are available.
A: 85%
B: 90%
C: 100%
D: 110%✔✔90%
4. A thermocouple is used with:
A: Intermittent pilot systems
B: Direct spark ignition
systems C: Glow coil ignition
systems
D: Standing pilot ignition systems✔✔Standing pilot ignition systems
3 / 14
5. The purpose of the gas pressure regulator is to:
A: Keep the color of the flame constant
B: Keep the high limit switch from tripping
C: Maintain a constant gas pressure at the burner
D: Allow the gas valve to operate smoothly and accurately✔✔Maintain
a constant gas pressure at the burner
6. The instrument used to measure outlet gas pressure is
the✔✔Velometer
B: Anemometer
C: Monometer
D: Draft gauge✔✔Monometer
7. he regulator on a natural gas furnace should be adjusted to supply
inches of pressure at the burners.
A: 11"
B: 10"
C: 3.5"
D: 2"✔✔3.5"