Virginia hic Exam Questions with correct
Answers
The MINIMUN length drywall screw for installing 1/2 inch gypsum board to wood studs
is - Answer- 1 1/4 inches
What is the MINIMUM breaking strength required of safety belt lanyards - Answer5,400 pounds
What is the MINIMUM clearance that combustible insulation MUST other heatproducing devices - Answer- 1 inch
What is the MAXIMUM flame spread index for insulation materials - Answer- 25
The amount of water per sack of cement is what controls all EXCEPT - Answer- Wear
resistance
The escape device for a trench over 4 feet deep MUST be within a MAXIMUM of -
Answer- 25 feet of the worker
What is the correct sequence for installing a bi-fold door - Answer- Top track, lower
track, insert bottom pivot, insert upper pivot
What is the MINIMUM height for a stairway handrail - Answer- 34 inches
How MUST rafters be framed to each other - Answer- With rectangular ties
The nailing holes in aluminum and vinyl siding are elongated to allow for - AnswerExpansion and contraction
What are batter boards - Answer- stakes and ledger boards marking building lines
The first step that needs to be taken prior to starting any excavation work is - Answercontracting the local utility companies
What is the MAXIMUM distance horizontal reinforcement can be placed from the top of
a masonry partition wall - Answer- 16 inches
What is the MINIMUM vertical reinforcement spacing for a reinforced concrete
foundation wall that is 7 feet high and 10 inches thick on type SP soil - Answer- 48
inches on center
A third stairway stringer should be used when the stair width exceeds - Answer- 30
inches
Unless otherwise specified, the standard guideline for spacing contraction joints is to
space them in feet - Answer- 2 times the stab depth in inches
What is the MINIMUM lap of riveted horizontal lap siding - Answer- 1 inches
For multiple-width masonry (mampostería de ancho múltiple) what is the MINIMUM
thickness of grout between masonry units and reinforcements? - Answer- 1/4 inch
What is the MAXIMUM dimension of the ventilation coverings for under-floor space -
Answer- 1/4 inch
The MOST specific information about the size and location of windows would be found
in a - Answer- Floor plan
What is the MINIMUM illumination for general constructions area lighting - Answer- 5
foot candles
in drywall 3 trim is used to - Answer- provide a finish edge
What is the MINIMUM number of anchor bolts REQUIRED for anchoring a 12 foot
section of wood still plate to a foundation - Answer- two bolts
What is the MINIMUM square footage of net clear opening area for an egress window in
a second floor sleeping area - Answer- 5.70 square feet
Which window type consists of an upper and a lower sash that slide vertically in the side
jambs - Answer- Double hung windows
Damp proofing on below-grade masonry foundation walls shall extend from the top of
the footing to - Answer- 6 inches above the finished grade
Scaffolds MUST remain a MINIMUM of how many feet from a 50-kV power line -
Answer- 10 feet
The REQUIREMENT for the thickness of masonry unit bed joints for the second course
shall be - Answer- 3/8 inches
What is not REQUIRED in exterior non bearing walls - Answer- a singles flat 2" x 4
member for opening up to 8 feet wide
What is the typical exposure of 3-tab asphalt shingles - Answer- 5 inches
A lengthwise grain separation between or through the growth rings of lumber is called a
- Answer- Shake
Category | exam bundles |
Comments | 0 |
Rating | |
Sales | 0 |