During acid base titration, titrant is added to the sample with -
ANSWER- Buret
When preparing diluted calibration standards from a stock standard, use
combination of the following to get the most precise standard -
ANSWER- Class A volumetric flask and class A volumetric pipet
At a given temperature, the intensity of the acidic or basic character of a
solution is indicated by - ANSWER- pH or hydrogen ion activity
pH measurement requires the following - ANSWER- voltmeter, glass
pH electrode, reference electrode, and a temperature compensating
device
Conductance measurements are temperature compensated to -
ANSWER- 25 degrees C
Conductivity meter is calibrated with - ANSWER- 0.0100 N potassium
chloride standard
Alkalinity is reported as - ANSWER- Alkalinity mg CaCO3/L
The hardness determination by EDTA titration measures - ANSWERCalcium and magnesium
The indicator for the hardness determination is - ANSWER- eriochrome
Black T
EPA acceptable primary standards for the turbidity determination
include - ANSWER- formazine only
BOD determination is an empirical test in which standardized lab
procedures are used to - ANSWER- determine the relative oxygen
requirements of wastewaters, effluents and polluted waters
Sample pretreatment for BOD - ANSWER- assuring that the samples are
neutralized to pH range between 6.5 and 7.5 and any residual chlorine
has been dechlorinated
Disinfection - ANSWER- Process designed to kill most microorganisms
in wastewater, including all essentially pathogenic bacteria
Fecal coliform bacteria - ANSWER- Bacteria found in feces of warm
blooded animals
Total coliform group - ANSWER- All of the aerobic and faculative
anaerobic, gram negative, nonspore-forming, rod shaped bacteria that
ferment lactose in 24-48 hours at 35 degrees C
Lab test results for an individual environmental sample within an
analytical batch may be rejected when - ANSWER- A known error has
occured
Precision is measured by - ANSWER- Analyzing replicate samples
Accuracy - ANSWER- The combination of bias and precision of an
analytical procedure, which reflects the closeness of a measured value to
a true value
Bias - ANSWER- Consistent deviation of measured values from the true
value, caused by systematic errors in a procedure
Precision - ANSWER- Measures the degree of agreement among
replicate analyses of a sample, usually expressed as the standard
deviation
Random Error - ANSWER- Consistent deviation of measured values
from the true value, caused by systematic errors in a procedure
Total Solids - ANSWER- Well mixed sample is evaporated in a weighed
dish and dried to constant weight in an oven at 103-105 degrees C