Manufacture of CFCs was banned as of December 31, _______?
A) 1994
B) 1995
C) 2000
D) 2010 - ANSWER- 1995
Positive evidence that CFCs are in the stratosphere comes from
____________? - ANSWER- Measurements of CFCs in air samples
taken from the stratosphere
Under EPAs regulations reclaimed refrigerant must meet standards for
purity before it can be resold - ANSWER- ARI 700
________recovery devices are so named because they depend on
components of the system. That is, they capture refrigerant with the
assistance of components in the air conditioning or refrigeration
equipment they are emptying - ANSWER- System-dependent
All devices used for refrigerant recovery must
meet___________standards. - ANSWER- EPA
An example of an HCFC refrigerant: - ANSWER- R-22
Which of the refrigerants listed below contain no chlorine?
A) CFCs
B)HCFCs
C) HFCs
D) ODCs - ANSWER- HFCs
Which refrigerant is an HFC?
A) R-123
B) R- 134a
C) R- 11
D) R- 22 - ANSWER- R-134a
Ozone in the stratosphere consist of molecules containing _________
oxygen atoms. - ANSWER- Three
_____ in refrigerants causes ozone destruction. - ANSWER- Chlorine
Recovery devices that can capture liquid and/ or vapor refrigerant
without the assistance of components in the air conditioning or
refrigerant equipment are known as _____. - ANSWER- Self-contained
Technicians are certified to recover refrigerant during the maintenance,
service, or repair of packaged A/C or refrigeration equipment with five
pounds or less of refrigerant if they receive a passing grade on
__________ examinations. - ANSWER- Type 1
Technicians are certified to recover refrigerant during the maintenance,
service, or repair of high-pressure equipment if they receive a passing
grade on which of the following examinations? - ANSWER- Type 2
(high pressure certificate)
______ refrigerants leak at uneven rates due to the differences in the
vapor pressures. - ANSWER- Blended
When evacuating a system, the hoses should be: - ANSWER- Equal to
or larger than vacuum pump inlet connection
When moisture exist in an operating system, which of the following is
the most likely to occur? - ANSWER- Acid will form
The size (capacity) of the vacuum pump and the size of the suction line
used will determine: - ANSWER- The length of dehydration time
To obtain an accurate vacuum reading during system evacuation, the
system vacuum gauge should be located: - ANSWER- As far from the
vacuum pump as possible
What factors affects the speed of evacuation? - ANSWER- -) the size of
the equipment being evacuated
-) the ambient temperature
-) the amount of moisture in the system
A system is dehydrated to: - ANSWER- Remove water and water vapor
Containers designated "refillable" by DOT are used for transporting
recovered pressurized refrigerant ________? - ANSWER- To meet
safety requirements
A fillable refrigerant cylinder must never be filled to more than ______
of its capacity by weight: - ANSWER- 80%
A cylinder with grey body and a yellow top indicates that the cylinder is
designated to hold: - ANSWER- Recovered refrigerant
Refrigerant vapors or mist should not be inhaled because: - ANSWERThey may cause heart irregularities and or unconsciousness
If corrosion is found within the body of a relief valve, the valve must be:
- ANSWER- replaced.
After refrigerant liquid transfer between recovery unit and the system
being emptied, you need to avoid trapping: - ANSWER- liquid
refrigerant between service valves.