TCFP INSPECTOR'S CLASS QUESTIONS QUESTIONS AND ANSWERS (2023/2024)

(VERIFIED ANSWERS)

1) Manual fire alarm boxes shall be located not more than ___ feet from the entrance to each exit.
 
  5
  10
  15
  20  
  25
 
  Feedback
907.5.2.1
Unanswered
86% got this correct
2) Horizontal and vertical sliding and rolling fire doors shall be inspected and tested __________ to confirm proper operation and full closure.
 
  Every 30 days
  Every 90 days
  Every 36 months
  Every 72 months
  Annually
 
  Feedback
703.4
Unanswered
62% got this correct
3) Combustible trim, excluding handrails and guardrails, shall not exceed ___ percent of the specific wall or ceiling areas to which it is attached.
 
  10
  15
  20
  25
 
  Feedback
804.1
Unanswered
86% got this correct
4) Candles and open flames are allowed to be used on or near decorative vegetation while immediately supervised.
 
  T
  F
 
  Feedback
806.4
Unanswered
92% got this correct
5) Swinging fire doors shall close from the _________ position and latch automatically.
 
  Partially open
  Partially closed
  Full open
 
  Feedback
703.2.3
Unanswered
67% got this correct
6) Combustible material shall not be stored in ________________. 

(check all that apply)
 
  Boiler rooms (Missed)
  Mechanical rooms (Missed)
  Lunch break rooms
  Electrical equipment rooms (Missed)
  Underground rooms
 
  Feedback
315.2.3
Unanswered
74% got this correct
7) Temporary wiring for electrical power and lighting installations is allowed for a period not to exceed ___ days.
 
  30
  60
  90
  180
 
  Feedback
605.9
Unanswered
65% got this correct
8) A permit is required to install stationary storage battery systems having a liquid capacity of more than ____ gallons.
 
  25
  50
  75
  100
 
  Feedback
105.7.2
Unanswered
66% got this correct
9) An operational permit is required  to use a building or portion thereof as a high-piled storage area exceeding _____ square feet.
 
  300
  400
  500
  600
 
  Feedback
105.6.22
Unanswered
72% got this correct
 
10) Covered mall buildings exceeding __________ square feet shall be provided with standby power systems that are capable of operating the emergency voice/alarm communication.
 
  25500
  40000
  50000
  75000
Unanswered
89% got this correct
11) Manual fire alarm boxes may be any color, approved by the fire code official, that contrasts the color of the location in which they are installed.
 
  T
  F
 
  Feedback
907.5.2.3
Unanswered
59% got this correct
12) Outside storage of combustible materials shall not be located within ___ feet of a property line.
 
  5
  10
  15
  20
 
  Feedback
315.3
Unanswered
64% got this correct
13) Classify the following based on occupancy:  Funeral parlor
 
  A-1
  A-2
  A-3
  A-4
  A-5
 
  Feedback
Ch. 2
Unanswered
51% got this correct
14) Classify the following based on occupancy:  Child care facilities that provide supervision and personal care on less than a 24 hour basis for more than 5 children 2 1/2 years of age or less.
 
  E
  I-2
  B
  I-4
 
  Feedback
pg. 26
Unanswered
77% got this correct
15) Extension cords and flexible cords shall not be a substitute for ______________.
 
 
  Possible correct answers:  
permanent wiring
 
  Feedback
605.5
Unanswered
56% got this correct
16) Combustible storage shall be kept a minimum of ___ feet from battery chargers.
 
  3
  5
  10
  15
 
  Feedback
309.2
Unanswered
61% got this correct
17) Classify the following based on occupancy:  Hotels (transient)
 
  R-1
  R-2
  R-3
  R-4
 
  Feedback
pg. 26
Unanswered
60% got this correct
18) An operational permit is required for the storage and handling of combustible fibers in quantities greater than __________.
 
  100 cubic feet
  100 square feet
  200 cubic feet
  200 square feet
 
  Feedback
105.6.7
Unanswered
81% got this correct
19) Commercial cooking systems for low-volume cooking operations such as places of worship, seasonal businesses and senior centers shall be inspected ________.
 
  Every month
  Every 3 months
  Every 6 months
  Every 12 months
 
  Feedback
Table 609.3.3.1
Unanswered
67% got this correct
20) The maximum travel distance to a fire extinguisher in a Class A, extra (high) hazard occupancy is ___ feet.
 
  30
  50
  75
  100
 
  Feedback
Table 906.3 (1)
Unanswered
83% got this correct
21) The minimum corridor width shall be not less than 44 inches.
 
  T
  F
 
  Feedback
1018.2
Unanswered
72% got this correct
22) Artwork and teaching materials shall be limited on walls of corridors to not more than ___ percent of the wall area.
 
  15
  20
  25
  30
 
  Feedback
807.4.4.2
Unanswered
56% got this correct
23) A manual actuation device shall be located at or near a means of egress from the cooking area a minimum of ___ feet and a maximum of ___ feet from the kitchen exhaust system.
 
  5, 10
  10, 15
  10, 20
  15, 20
  15, 25
 
  Feedback
904.11.1
Unanswered
64% got this correct
24) An operational permit is not required to melt, cast, heat treat or grind less than 10 pounds of magnesium.
 
  T
  F
 
  Feedback
105.6.28 read carefully
Unanswered
65% got this correct
25) Stairways shall have a minimum headroom clearance of ___ inches measured vertically from a line connecting the edge of the nosings.
 
  78
  80
  82
  84
 
  Feedback
1009.2
Unanswered
76% got this correct
 
26) Where there is a conflict between a general requirement and a specific requirement, the __________  shall be applicable.
 
  General requirement
  Specific requirement
  Most stringent
  Least stringent
Unanswered
57% got this correct
27) Hand-held portable fire extinguishers having a gross weight not exceeding ___ pounds shall be installed so that their tops are not more than ___ feet above the floor.
 
  40, 3
  40, 5
  40, 3.5
  40, 5.5
 
  Feedback
906.9.1
Unanswered
93% got this correct
28) Fire alarm, sprinkler and standpipe systems shall be maintained in an operable condition at all times in vacant premises.
 
  T
  F
 
  Feedback
311.2.2
Unanswered
79% got this correct
29) The first emergency evacuation drill of each school year shall be conducted within _____ days of the beginning of classes.
 
  10
  14
  21
  28
 
  Feedback
408.3.1
Unanswered
63% got this correct
30) An operational permit is required for the storage, use, or handling at NTP of _____ of compressed corrosive gas.
 
  200 cubic feet
  504 cubic feet
  6000 cubic feet
  Any amount
 
  Feedback
Table 105.6.8
Unanswered
63% got this correct
31) The height of manual fire alarm boxes shall be a minimum of ___ inches and a maximum of ___ inches measured vertically, from the floor level to the activating handle or lever of the box.
 
  36, 42
  36, 48
  42, 48
  44, 48
 
  Feedback
907.5.2.2
Unanswered
67% got this correct
32) The minimum required distance from a structure for open burning shall not be less than ___ feet where the pile size is ___ feet or less in diameter and ___ feet or less in height.
 
  50, 3, 2
  50, 2, 3
  25, 3, 2
  25, 2, 3
 
  Feedback
307.4 ex. 2
Unanswered
56% got this correct
33) Bulk storage of tires is defined as storage of tires where the area available for storage exceeds _________ cubic feet.
 
  5000
  10000
  15500
  20000
 
  Feedback
902
Unanswered
52% got this correct
34) Portable outdoor fireplaces shall not be operated within ___ feet of a structure or combustible material.
 
  5
  10
  15
  20
 
  Feedback
307.4.3
Unanswered
58% got this correct
35) Permit amounts for cryogenic fluids are found in which table?
 
 
  Possible correct answers:  
105.6.10, table 105.6.10, Table 105.6.10
 
  Feedback
pg. 7
Unanswered
66% got this correct
36) Vehicle impact protection guard posts shall be set with the top of the posts not less than ___ feet above the ground.
 
  3
  3.5
  4
  4.5
 
  Feedback
312.2 (4)
Unanswered
67% got this correct
37) Where connected to a fuel-oil piping system, the maximum amount of fuel oil storage allowed outside above ground without additional protection shall be _____ gallons.
 
  50
  200
  350
  660
 
  Feedback
603.3.1
Unanswered
80% got this correct
38) Fire apparatus access roads shall have an unobstructed width of not less than ___ feet and an unobstructed vertical clearance of not less than ___ feet ___ inches.
 
  20, 10, 6
  20, 13, 6
  22, 12, 8
  22, 14, 10
 
  Feedback
503.2.1
Unanswered
72% got this correct
 
39) Classify the following based on occupancy:  Sales room
 
  B
  A-3
  M
  S-2
Unanswered
56% got this correct
40) Turnstiles more than ___ inches high shall meet the requirements for revolving doors.
 
  30
  36
  39
  42
 
  Feedback
1008.3.1
Unanswered
46% got this correct
41) Extension cords shall be plugged directly into an approved receptacle, power tap or multiplug adapter and, except for approved mutliplug extension cords, shall serve _________.
 
 
  Possible correct answers:  
only one portable appliance
 
  Feedback
605.5.1
Unanswered
62% got this correct
42) Official records shall be retained for not less than 3 years.
 
  T
  F
 
  Feedback
104.6
Unanswered
61% got this correct
43) High-rise buildings require emergency evacuation drills ________ and shall include ________.
 
  Quarterly, employees
  Quarterly, all occupants
  Annually, employees
  Annually, all occupants
 
  Feedback
Table 405.2
Unanswered
73% got this correct
44) Classify the following based on occupancy:  Fences more than 6 feet high.
 
  F-1
  F-2
  U
  S-2
  M
 
  Feedback
Ch. 2
Unanswered
69% got this correct
45) With regards to premises identification, address numbers shall be a minimum of ___ inches high with a minimum stroke of ___ inch(es).
 
  3, 0.5
  4, 0.5
  3, 1
  4, 1
 
  Feedback
505.1
Unanswered
56% got this correct
46) An approved fire safety and evacuation plan shall be prepared and maintained for Group M buildings having an occupant load of _____ or more persons or more than _____ persons above or below the lowest level of exit discharge.

(check all that apply)
 
  100 (Missed)
  200
  300
  400
  500 (Missed)
 
  Feedback
404.2 (11)
Unanswered
59% got this correct
47) Dumpsters and containers with an individual capacity of 1.5 cubic yards or more shall not be stored in buildings or placed within ___ feet of combustible walls, openings, or combustible eave lines.
 
  3
  5
  10
  15
 
  Feedback
304.3.3
Unanswered
61% got this correct
48) An operational permit is required to operate an air-supported temporary membrane structure or a tent having an area in excess of _____ square feet.
 
  200
  250
  400
  500
 
  Feedback
105.6.43
Unanswered
68% got this correct
49) An operational permit is required to manufacture, store or handle an aggregate quantity of __________ aerosol products in excess of 500 pounds net weight.
 
  Level 2
  Level 3
  Level 4
  Both B and C
  Both A and B
 
  Feedback
105.6.1
Incorrect
56% got this correct
50) Hand-held portable fire extinguishers having a gross weight exceeding ___ pounds shall be installed so that their tops are not more than ___ feet above the floor.
 
  40, 3
  40, 5
  40, 3.5
  40, 5.5  

No comments found.
Login to post a comment
This item has not received any review yet.
Login to review this item
No Questions / Answers added yet.
Price $11.00
Add To Cart

Buy Now
Category Exams and Certifications
Comments 0
Rating
Sales 0

Buy Our Plan

We have

The latest updated Study Material Bundle with 100% Satisfaction guarantee

Visit Now
{{ userMessage }}
Processing