BOMA-HVAC
Study online at https://quizlet.com/_ewon6m
1. The man whose work is considered the real beginning of the science of air-conditioning _____.
Willis Carrier
2. Psychrometry refers to the relationship between
_____ and _____.
Humidity; air
3. The amount of moisture in the air compared to
how much it can hold is _____.
Relative humidity
4. The human bodies well being depends upon the
_____.
Bodies metabolism
5. The device used to determine the moisture content of air is the _____
psychrometer
6. Of the fuels listed the one that is the most efficient is _____.
Gas
7. The effective temperature takes into consideration the effect of _____ and _____.
Humidity; temperature
8. Air conditioning is the control of the _____,
_____, _____ and _____.
Temperature, humidity,
purity and distribution of
air.
9. The element that makes up the greatest percentage by volume of air is _____.
Nitrogen
10. Steam gives off a great amount of heat because
of its _____.
Specific heat
11. The velocity of air moving thru a fan system is
expressed in _____.
Feet per minute
12. What volume of air will move thru a duct 24x18 at
velocity of 450 feet per minute?
1350 cfm
13. The following types of fans are classified as centrifugal fans.
Forward curved, radial
and backward curved
1 / 8
BOMA-HVAC
Study online at https://quizlet.com/_ewon6m
14. Select the statement that does not apply to backward inclined fans.
Has an overloading
BHP horse power curve.
15. The quantity of air moving thru a fan system is
expressed in _____.
Cubic feet per minute
16. The instrument used to measure air pressure in
duct is the _____.
Monometer
17. Air flow thru a duct has the highest _____. Velocity near the center
of the duct.
18. Select the statement which does not apply to the
fan laws.
Static pressure in a duct
increases as the velocity decreases.
19. Variable air volume system feature is _____. Varies the volume of air
with space temperature
conditions
20. Double duct systems are _____. ?
21. The purpose of a primary control is to _____. Start or stop the system
22. A pressurestat responds to _____. System pressure
23. The oil safety switch is operated by _____. Oil
pressure
24. A low limit control _____. ?
25. A high limit control _____. ?
26. Limit controls _____. Are wired into the circuit
in series
27. A diulating switch is used to _____. Change proportional action to two position control.
2 / 8
BOMA-HVAC
Study online at https://quizlet.com/_ewon6m
28. A ratio relay is used to _____. Provide sequence control of more than one actuator.
29. A proportional control: Where a movement
from the set point produces a proportional
movement of the actuator
30. A three way diverting valve: has two outlets and one
common inlet
31. Heat will continue to flow between two bodies
until they have the same amount of _____.
Sensible heat