BOMA-HVAC Study online at https://quizlet.com/_ewon6m 1. The man whose work is considered the real beginning of the science of air-conditioning _____. Willis Carrier 2. Psychrometry refers to the relationship between _____ and _____. Humidity; air 3. The amount of moisture in the air compared to how much it can hold is _____. Relative humidity 4. The human bodies well being depends upon the _____. Bodies metabolism 5. The device used to determine the moisture content of air is the _____ psychrometer 6. Of the fuels listed the one that is the most efficient is _____. Gas 7. The effective temperature takes into consideration the effect of _____ and _____. Humidity; temperature 8. Air conditioning is the control of the _____, _____, _____ and _____. Temperature, humidity, purity and distribution of air. 9. The element that makes up the greatest percentage by volume of air is _____. Nitrogen 10. Steam gives off a great amount of heat because of its _____. Specific heat 11. The velocity of air moving thru a fan system is expressed in _____. Feet per minute 12. What volume of air will move thru a duct 24x18 at velocity of 450 feet per minute? 1350 cfm 13. The following types of fans are classified as centrifugal fans. Forward curved, radial and backward curved 1 / 8 BOMA-HVAC Study online at https://quizlet.com/_ewon6m 14. Select the statement that does not apply to backward inclined fans. Has an overloading BHP horse power curve. 15. The quantity of air moving thru a fan system is expressed in _____. Cubic feet per minute 16. The instrument used to measure air pressure in duct is the _____. Monometer 17. Air flow thru a duct has the highest _____. Velocity near the center of the duct. 18. Select the statement which does not apply to the fan laws. Static pressure in a duct increases as the velocity decreases. 19. Variable air volume system feature is _____. Varies the volume of air with space temperature conditions 20. Double duct systems are _____. ? 21. The purpose of a primary control is to _____. Start or stop the system 22. A pressurestat responds to _____. System pressure 23. The oil safety switch is operated by _____. Oil pressure 24. A low limit control _____. ? 25. A high limit control _____. ? 26. Limit controls _____. Are wired into the circuit in series 27. A diulating switch is used to _____. Change proportional action to two position control. 2 / 8 BOMA-HVAC Study online at https://quizlet.com/_ewon6m 28. A ratio relay is used to _____. Provide sequence control of more than one actuator. 29. A proportional control: Where a movement from the set point produces a proportional movement of the actuator 30. A three way diverting valve: has two outlets and one common inlet 31. Heat will continue to flow between two bodies until they have the same amount of _____. Sensible heat

No comments found.
Login to post a comment
This item has not received any review yet.
Login to review this item
No Questions / Answers added yet.
Price $6.00
Add To Cart

Buy Now
Category exam bundles
Comments 0
Rating
Sales 0

Buy Our Plan

We have

The latest updated Study Material Bundle with 100% Satisfaction guarantee

Visit Now
{{ userMessage }}
Processing